400 V or 230 V: the right connection
What your electrician needs to know before the sauna arrives.

Every electric stove in our configurator delivers 9 kW. That is enough to bring the cabin to 80–90 °C in roughly 45 to 60 minutes. It is also more than a normal household socket can supply.
A 9 kW stove needs a three-phase 400 V connection. A household socket will not do.
Why 400 V?
At 230 V, 9 kW means around 39 amps on a single line. Spread over three phases at 400 V, each phase carries about 13 A. That is why sauna stoves of this size are wired three-phase, typically protected with 3 × 16 A. Small stoves up to about 3.6 kW do run on 230 V, but they are made for indoor cabins, not for an outdoor sauna in a Swiss winter.
From the house to the sauna
The cable usually runs underground in a protective conduit from the main distribution board to the sauna. Its cross-section depends on the length and the fuse; on longer runs the electrician sizes it up to limit the voltage drop. The circuit needs its own residual-current device (RCD).

Only a licensed electrician
In Switzerland, fixed installations may only be carried out by a licensed installer, who then issues a safety certificate (SiNa). This is not paperwork for its own sake: it is the document your insurer will ask for.
We coordinate a local partner. Depending on the distance and the state of the distribution board, the connection costs CHF 2,300 to 4,500. Ask early whether your board has room for a 400 V circuit.
Ask early whether your board has room for a 400 V circuit.
Or wood after all?
If there is no power line, a wood-burning stove is the alternative: no connection needed, the crackle of the fire included. In return you need a chimney and the fire-safety inspection described in our permit guide.
Questions about your site? We’ll work through them with you.
Get advice